Blood Transfusion–Acquired Hemoglobin C

Adrian A. Suarez, Jacek M. Polski, Brenda J. Grossman, Marilyn F.M. Johnston

Archives of Pathology & Laboratory Medicine · 1999 · 14 citations · 1 references

Concepts

Abstract

Unexpected and confusing laboratory test results can occur if a blood sample is inadvertently collected following a blood transfusion. A potential for transfusion-acquired hemoglobinopathy exists because heterozygous individuals show no significant abnormalities during the blood donor screening process. Such spurious results are infrequently reported in the medical literature. We report a case of hemoglobin C passively transferred during a red blood cell transfusion. The proper interpretation in our case was assisted by calculations comparing expected hemoglobin C concentration with the measured value. A review of the literature on transfusion-related preanalytic errors is provided.

References

1