Química Nova · 2014 · 18 citations · 2 references
Natural SciencesChemistryPharmaceutical AnalysisAnalytical ChemistryElectroanalytical MethodsElectrochemistryBioanalytical Method ValidationElectroanalytical ChemistryBoron-doped Diamond ElectrodesDetection Limit AssessmentMethod Detection LimitSquare-wave VoltammetryVoltammetric DetectionVoltammetry
A simple procedure is described for the determination of scopolamine by square-wave voltammetry using a cathodically pretreated boron-doped diamond electrode. Cyclic voltammetry studies indicate that the oxidation of scopolamine is irreversible at a peak potential of 1.59 V (vs. Ag/AgCl (3.0 mol L-1 KCl)) in a 0.50 mol L-1 sulfuric acid solution. Under optimized conditions, the analytical curve obtained was linear (r = 0.9996) for the scopolamine concentration range of 1.0 to 110 µmol L-1, with a detection limit of 0.84 µmol L-1. The method was successfully applied to the determination of scopolamine in pharmaceutical formulations with minimum sample preparation.
2
Ayman A. Gouda, Zeineb El Shafey, Nagda Hossny et al. · Spectrochimica Acta Part A Molecular and Biomolecular Spectroscopy · 2007 · 32 citations