Compact energy storage using a modified-spiral PFL

S. Friedman, R. Limpaecher, M. Sirchis

2003 · 14 citations · 1 references

Concepts

Abstract

The pulse length available from a coaxial PFL (pulse-forming line) of given length and dielectric constant has been doubled using a modified spiral technique. The modified spiral consists of a cylinder formed from a large number of insulated cables which are first laid parallel to the PFL axis and then given a moderate twist. The PFL is essentially a helical delay line in a form which accomplishes substantial pulse stretching without introducing significant turn-to-turn voltage gradients or distortion of the pulse shape. The technique can be used to increase the energy stored per unit length for a PFL of fixed impedance and pulse duration.< <ETX xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">&gt;</ETX>

References

1