Circulation Arrhythmia and Electrophysiology · 2013 · 54 citations · 24 references
MedicineCardiologySurgeryInterventional CardiologyUltrasonographyUltrasoundAnticoagulant ManagementAtrial FibrillationCardiac CatheterizationEchocardiographic Hemodynamic AssessmentPulmonary EmbolismThrombosisActivated Clotting TimeIntracardiac EchocardiographyPulmonary Vein IsolationSystemic AnticoagulationTherapeutic AnticoagulationThromboembolic Complication DetectionTranscranial Ultrasound Imaging
BACKGROUND: Pulmonary vein isolation has increasingly been used to cure atrial fibrillation, but concerns have recently been raised that subclinical brain damage may occur because of microembolization during these procedures. We compared the occurrence of bubble formation seen on intracardiac echocardiography and the microembolic signals (MESs) detected by transcranial Doppler on the use of different ablation techniques and anticoagulation strategies. METHODS AND RESULTS: This prospective study included 35 procedures in 34 consecutive patients (age, 52; SD, 12.8 years; female:male 9:25). Pulmonary vein isolation was performed with a cryoballoon and the conventional anticoagulation protocol (activated clotting time >250 s) in 10 procedures (group 1), with a multipolar duty-cycled radiofrequency pulmonary group 2), and with regime a pulmonary vein ablation catheter with an aggressive anticoagulation (activated clotting time >320 s) in 13 procedures (group 3). The mean total numbers of MESs detected during the procedures were 833.7 (SD, 727.4) in group 1, 3142.6 (SD, 1736.4) in group 2, and 2204.6 (SD, 1078.1) in group 3 (P=0.0005). MESs were detected mostly during energy delivery in the pulmonary vein ablation catheter groups, whereas a relatively even distribution of emboli formation was seen during cryoballoon ablations. A significant correlation was found in all groups between the degree of bubble formation on intracardiac echocardiography and the number of MESs (P=0.0000). CONCLUSIONS: Duty-cycled radiofrequency ablation is associated with significantly more MESs, even when more aggressive anticoagulation is applied. With both techniques most of these microemboli are gaseous in nature.
24
Consensus on Microembolus Detection by TCD
E. Bernd Ringelstein, Dirk W. Droste, Viken L. Babikian et al. · Stroke · 1998 · 634 citations · Full text
Lower Incidence of Thrombus Formation With Cryoenergy Versus Radiofrequency Catheter Ablation
Paul Khairy, Patrick Chauvet, John W. Lehmann et al. · Circulation · 2003 · 515 citations
Medicine, Cardiology, Anesthesia +13
Radiofrequency Catheter Ablation of Atrial Fibrillation: A Cause of Silent Thromboembolism?
Fiorenzo Gaïta, Domenico Caponi, Martina Pianelli et al. · Circulation · 2010 · 358 citations · Full text
Medicine, Cardiology, Surgery +17