Developments of a New 1-Dimensional$gamma$-Ray Position Sensor Using Scintillators Coupled to a Si Strip Detector

T. Itoh, M. Kokubun, Takeshi Takashima, Tetsutaro HONDA, Kazuo Makishima, Takaaki Tanaka, Takayuki Yanagida, Shinya Hirakuri, R. Miyawaki, H. Takahashi,

IEEE Transactions on Nuclear Science · 2006 · 78 citations · 11 references

Concepts

Abstract

In order to operate an “improved” Fourier synthesis imager at higher photon energies than are accessible with solid-state detectors, we developed a new one-dimensional <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$gamma$</tex> -ray position sensor consisting of inorganic scintillators whose light is read out by a silicon strip detector (SSD). The SSD is read out through stripped p-electrodes (DC-coupled, 32 channels at 400 <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$mu$</tex> m pitch). The n-side of the SSD does not have a metallic surface, and has a relatively good optical transparancy. A stack of optically isolated thin CsI(Tl) scintillator plates (10 mm <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$,times,$</tex> 10 mm in area and 0.3 mm thick) is attached, edge-on, to the n-side of the SSD. When a <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$gamma$</tex> -ray photon hits the stacked scintillator, the generated scintillation light is detected by the SSD, with the signal pulse-height largest in the p-electrode which is just beneath the CsI plate hit by the <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$gamma$</tex> -ray. The 32-channel outputs from the SSD are acquired simultaneously for each event with a low-noise analog ASIC. The <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$gamma$</tex> -ray position can be calculated as a weighted mean of pulse heights. Using this system, we have obtained a position resolution significantly finer than 1 mm for <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$gamma$</tex> -rays with energies greater than <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$sim500$</tex> keV up to <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$sim$</tex> 1300 keV.

References

11