Continuous Emissions Monitoring Using Spark-Induced Breakdown Spectroscopy

Amy J. R. Hunter, Joseph R. Morency, Constance Senior, Steven J. Davis, Mark E. Fraser

Journal of the Air & Waste Management Association · 2000 · 30 citations · 1 references

DOIFull text

Open access

Concepts

Abstract

A new technology for monitoring airborne heavy metals on aerosols and particulates based on spark-induced breakdown spectroscopy (SIBS) was evaluated at a joint U.S. Environmental Protection Agency (EPA)/U.S. Department of Energy test at the rotary kiln incinerator simulator (RKIS) facility at EPA/Research Triangle Park, NC, in September 1997. The instrument was configured to measure lead and chromium in a simulated combustion flue gas in real time and in situ at target levels of 15 and 75 micrograms/dry standard cubic meters. Actual metal concentrations were measured during the tests using EPA Reference Method (RM) 29. The SIBS technology detected both lead and chromium at the low- and high-level concentrations. Additionally, the hardware performed without failure for more than 100 hr of operation and acquired data for 100% of the RM tests. The chromium data were well correlated with concentration increases resulting from duct operations and pressure fluctuations that are known to entrain dust.