Heat shock proteins 47 and 70 expression in rodent skin model as a function of contact cooling temperature: Are we overcooling our target?

15

Citations

32

References

2007

Year

Abstract

Our data would suggest contact cooling temperatures 5 degrees C and below completely protects through the entire dermis. There was no evidence of epidermal injury with protective cooling at any temperature between 0 and 25 degrees C. Warmer temperatures are safe and adequately protect the epidermis in this model.