Accelerated Healing of Distal Radial Fractures with the Use of Specific, Low-Intensity Ultrasound. A Multicenter, Prospective, Randomized, Double-Blind, Placebo-Controlled Study*

Thomas Kristiansen, John P. Ryaby, Joan McCabe, John J. Frey, Linda R. Roe

Journal of Bone and Joint Surgery · 1997 · 590 citations · 21 references

Concepts

TL;DR

The study aimed to determine whether a specifically programmed, low‑intensity, pulsed ultrasound device could shorten radiographic healing time for dorsally angulated distal radius fractures treated with cast. Sixty patients were randomized within seven days of fracture to use either the active ultrasound or a placebo device for 20 min daily at home over ten weeks, with identical devices except for energy output, and were evaluated by serial clinical exams and radiographs at multiple time points. Ultrasound treatment reduced time to union to 61 days versus 98 days for placebo, accelerated all radiographic healing stages, and lowered loss of reduction from 43 % to 20 % and the duration until loss ceased from 25 days to 12 days, demonstrating accelerated healing and decreased loss of reduction.

Abstract

A multicenter, prospective, randomized, double-blind, placebo-controlled clinical trial was conducted to test the efficacy of a specifically programmed, low-intensity, non-thermal, pulsed ultrasound medical device for shortening the time to radiographic healing of dorsally angulated fractures (negative volar angulation) of the distal aspect of the radius that had been treated with manipulation and a cast. Sixty patients (sixty-one fractures) were enrolled in the study within seven days after the fracture. The patients used either an active ultrasound device (thirty fractures) or a placebo device (thirty-one fractures) daily for twenty minutes at home for ten weeks. The two types of devices were identical except that the placebo devices emitted no ultrasound energy. Clinical examination was performed and radiographs were made at one, two, three, four, five, six, eight, ten, twelve, and sixteen weeks after the fracture by each site investigator. The time to union was significantly shorter for the fractures that were treated with ultrasound than it was for those that were treated with the placebo (mean [and standard error], 61 ± 3 days compared with 98 ± 5 days; p < 0.0001). Each radiographic stage of healing also was significantly accelerated in the group that was treated with ultrasound as compared with that treated with the placebo. Compared with treatment with the placebo, treatment with ultrasound was associated with a significantly smaller loss of reduction (20 ± 6 per cent compared with 43 ± 8 per cent; p < 0.01), as determined by the degree of volar angulation, as well as with a significant decrease in the mean time until the loss of reduction ceased (12 ± 4 days compared with 25 ± 4 days; p < 0.04). We concluded that this specific ultrasound signal accelerates the healing of fractures of the distal radial metaphysis and decreases the loss of reduction during fracture-healing.

References

21