Acta Paediatrica · 2001 · 23 citations · 20 references
MedicinePharmacologyDiagnostic ToxicologyHepatic PharmacokineticsHepatologyBiliary Tract DisordersBiomarkers Of Liver InjuryCholestatic Liver InjuryHepatic Function TestingLiver DiseaseLiver Function TestsBiliary Atresia ImagingExtrahepatic CholestasisGamma-glutamyl TransferaseIdiopathic EtiologyInterpretation Of Liver Function TestsLiver Enzyme AbnormalitiesLiver Function Test InterpretationNeonatal Hepatitis
UNLABELLED: Hepatic technetium-99m-mebrofenin iminodiacetate (99mTc-mebrofenin IDA) scans and serum gamma-glutamyl transpeptidase (GGTP) have high sensitivity for extrahepatic biliary atresia (EHBA). This study was based on the hypothesis that the interpretation of results of 99mTc-mebrofenin IDA scans and serum GGTP levels in series would result in a reduction of the false positivity observed with these tests individually. The aetiology of neonatal cholestasis in 132 study patients was: 25% (33/132) EHBA, 45.5% (60/132) neonatal hepatitis (NH) with an identifiable cause and 19.7% (26/132) idiopathic NH. Of the various clinical, biochemical and imaging parameters that were significantly different between patient groups, sensitivity for EHBA was: serum GGTP > or = 150 IU l(-1) (100%), 99mTc-mebrofenin IDA scans (100%), pale stools (82.8%) and total serum bilirubin > or = 12 mg dl(-1) (66%). However, specificity ranged from 48.5 to 79%. Of the 63 patients who had non-excreting IDA scans, operative cholangiograms could be avoided on the basis of a specific aetiological diagnosis of NH, made concurrently, in only 9 infants. The rest (54) underwent operative cholangiograms; 21 (39%) of these had patent biliary trees and therefore underwent the procedure unnecessarily. If serum GGTP (< 150 IU l(-1)) had been used as a screen after IDA scanning in these 54 patients, operative cholangiograms could have been avoided in another 12 patients and thereafter only 9/42 (21%) of the operative cholangiograms would have been considered unnecessary. CONCLUSION: A diagnostic algorithm is proposed wherein serum GGTP level (at a cut-off level that maintains 100% sensitivity for EHBA) is used in series with non-excreting 99mTc-mebrofenin IDA scans (for patients with no specific aetiological label). This strategy reduces the false positivity of individual tests.
20
LATE REFERRAL FOR BILIARY ATRESIA— MISSED OPPORTUNITIES FOR EFFECTIVE SURGERY
Giorgina Mieli‐Vergani, B. Portman, E R Howard et al. · The Lancet · 1989 · 282 citations
Woo-Hyun Park, Soon-Ok Choi, Hee-Jung Lee et al. · Journal of Pediatric Surgery · 1997 · 134 citations · Full text
Medicine, Pediatrics, Radiology +17
Progress in the treatment of biliary atresia
Ryoji Ohi, Masahiro Hanamatsu, Izumi Mochizuki et al. · World Journal of Surgery · 1985 · 123 citations
Medicine, Surgery, Hepatology +10