Radiology · 1960 · 88 citations · 0 references
MedicineGynecologyOncologyGynecologic OncologyRadiobiologySurgical OncologyExternal Beam RadiotherapyGynecologic Cancer RadiotherapyRadiation TherapyApplicator PlacementCervical Cancer RadiotherapyInvasive Cervical CarcinomaRadiation Exposure Management
The main feature of the applicator to be described here is the elimination of radiation exposure during its introduction into the uterus and vagina. This is accomplished by “afterloading.” In the operating room, only the empty applicator is inserted. After the patient has returned to her room, the radioactive sources are introduced through three tubes which extend from the applicator through the vagina to the outside. The applicator, as used in an uncomplicated cervical carcinoma, is shown in the accompanying figure. Uterus and vagina are schematically outlined. To place the applicator, the empty central tube is first introduced into the uterine cavity. Next, the two lateral balls with empty tubes attached are inserted, one after the other, into the right and left vaginal fornices. These lateral balls are guided into position by an alignment plate which has holes for the central and the lateral tubes. The position of the inserted applicator is maintained by additional balls on the central tube and by the customary packing or, alternatively, by sutures. For the tubing as well as for the balls, nylon has proved most satisfactory. Individual adjustments are made at the time of insertion by varying the length of the tube in the uterus and by choosing balls of various diameters. The dose to the rectum and bladder can be reduced by lead or tungsten inserts in the balls, by packing, or by one or two Foley bag catheters (not shown in drawing), which increase the distance of the applicator to rectum and/or bladder. The Foley catheters are securely held in position by holes in the alignment plate. As radioactive sources, small cylindrical encapsulated sources of cobalt 60, iridium 192, europium 152/154, cesium 137, radium or radon can be used. These are loaded into thin tubing which fits into the three larger tubes of the inserted applicator. Usually one source is inserted into the center of each lateral ball. In the central tube, several sources are arranged in tandem from the tip to the level of the cervix. Additional sources are used in the central tube if irradiation of the vagina is desired. The dose distribution is controlled by using sources of different strength and by their removal at different times. In interstitial therapy the principle of “after-loading” was used as early as 1910 by Abbe. In recent years, it has been applied by Mowatt and Stevens, as well as by Suit and by the present writer. As far as we know, afterloading has not yet been utilized in the treatment of carcinoma of the uterus.