Circulation Cardiovascular Interventions · 2009 · 10 citations · 12 references
MedicineRadiologySurgeryDiagnostic ImagingUltrasonographyUltrasoundCarotid Artery DiseaseCarotid Artery StentingIntravascular ImagingStent PlacementVascular UltrasonographyVascular UltrasoundCarotid Artery StenosisCarotid Artery UltrasonographyCarotid Artery UltrasoundCarotid Duplex UltrasonographyIn-stent ThrombosisOperating Characteristic CurvesReceiver Operating Characteristic AnalysisRestenosis After Stenting
BACKGROUND: Duplex ultrasonography criteria for assessing the severity of carotid artery (CA) in-stent restenosis are not well established. METHODS AND RESULTS: We analyzed 39 patients (40 CAs) who underwent CA stenting with baseline and 6-month follow-up carotid duplex ultrasonography and intravascular ultrasound. Intravascular ultrasound measurements included minimum luminal diameter, percent diameter, and lumen area stenosis. Duplex ultrasonography measurements included peak systolic velocity (PSV), percentage change in PSV, end-diastolic velocity (EDV), and internal-to-common CA PSV ratio (ICA/CCA). Receiver operating characteristic curves assessed each duplex measurement to detect >or=50% diameter, >or=75% lumen area stenosis, and minimum luminal diameter <3 mm at follow-up. At 6-month intravascular ultrasound follow-up, >or=50% diameter and >or=75% lumen area CA in-stent restenosis occurred in 20% and 25%, respectively; minimum luminal diameter <3 cm occurred in 48%. Area under receiver operating characteristic curves for PSV, EDV, and ICA/CCA were 0.85, 0.96, and 0.89 for >or=50% diameter stenosis and 0.89, 0.93, and 0.88 for >or=75% lumen area stenosis, respectively. Optimal PSV, EDV, and ICA/CCA criteria to detect >or=50% diameter and >or=75% lumen area CA in-stent restenosis were greater compared with those for native CA. A >98% increase in PSV had the highest specificity, whereas the combination of EDV >41 cm/s and ICA/CCA >2 had the highest sensitivity in detecting >or=75% lumen area CA in-stent restenosis. CONCLUSIONS: PSV, EDV, and ICA/CCA PSV ratio were good discriminators for detecting significant diameter and lumen area greater compared with those for native CA. The combination of duplex velocity criteria increases diagnostic accuracy.
12
Global experience in cervical carotid artery stent placement
Michael H. Wholey, Michael H. Wholey, Klaus Mathias et al. · Catheterization and Cardiovascular Interventions · 2000 · 507 citations · Full text
Medicine, Neurosurgery, Surgery +16
Duplex ultrasound velocity criteria for the stented carotid artery
Brajesh K. Lal, Robert W. Hobson, Babak Tofighi et al. · Journal of Vascular Surgery · 2008 · 208 citations · Full text
Medicine, Neurosurgery, Radiology +14
William E. Faught, Mark A. Mattos, Paul S. van Bemmelen et al. · Journal of Vascular Surgery · 1994 · 198 citations
Carotid artery stenting: is there a need to revise ultrasound velocity criteria?
Brajesh K. Lal, Robert W. Hobson, Jonathan Goldstein et al. · Journal of Vascular Surgery · 2003 · 176 citations · Full text
Medicine, Neurosurgery, Surgery +14