European Heart Journal · 2010 · 18 citations · 15 references
MedicineCardiologyRadiologyCardiothoracic SurgeryDiagnostic ImagingDiagnostic RadiologyAortic ImagingAortic StenosisAortic SurgeryCardiovascular ImagingComputed TomographyVascular ImagingAngulation MeasurementAortic Diameter AssessmentAortic Imaging MeasurementsAortic Root AnatomyCardiac Valvular AssessmentComputed Tomography AngiographyInter-rater ReliabilityTomography
AIMS: Reliable assessment of the aortic valvar apparatus (AVAp) is essential as it may facilitate consistent outcomes with percutaneous aortic valvar therapies. The commonly referenced aortic annulus is problematic since this measurement does not correspond to any actual anatomic structure. We aim to describe a reliable method of measuring relevant structures of the AVAp based on widely available computed tomography analyses. METHODS AND RESULTS: Retrospective analysis of computed tomograms of 75 patients with severe aortic stenosis (45 females, age 81.2 +/- 7.8 years). Curved multiplaner reconstruction technique was used to measure average diameters of the 'Aortic Leaflets Basal Attachment Plane' (ALBAP), sinuses of Valsalva (SV), sinutubular junction (STJ), ascending aorta (AA), and distance from coronary arteries to the base of the cusps. Angulation between the AA and the left ventricle (LV) was measured in one plane that included the LV inflow long axis and the maximum visualization of the aortic root. Inter-rater reliability and absolute agreement among three raters were evaluated. Intra-class correlation coefficients for ALBAP, SV, STJ, and AA diameters were 0.90, 0.99, 0.95, and 0.94, respectively (P < 0.001) with 95% limits of agreement of the observed differences falling in the less than 1 mm range. Intra-class correlation coefficients were 0.82 for the angle and 0.61 and 0.78 for distances to the right and left coronary arteries (P < 0.001). CONCLUSION: This method showed a high degree of inter-rater reliability and absolute agreement for AVAp diameters. Agreement was lower for AA-LV angle and distance to coronary artery measurements, emphasizing the need for software improvements and standardized image acquisition protocols.
15
Eberhard Grube, Gerhard Schüler, Lutz Buellesfeld et al. · Journal of the American College of Cardiology · 2007 · 948 citations
Medicine, Cardiology, Surgery +16
Percutaneous Aortic Valve Implantation Retrograde From the Femoral Artery
John G. Webb, Mann Chandavimol, Christopher Thompson et al. · Circulation · 2006 · 901 citations · Full text
Medicine, Cardiology, Surgery +7
Nicolò Piazza, Eberhard Grube, Ulrich Gerckens et al. · EuroIntervention · 2008 · 629 citations
Medicine, Cardiology, Surgery +17
Transapical Minimally Invasive Aortic Valve Implantation
Thomas Walther, Paul Simon, Todd Dewey et al. · Circulation · 2007 · 619 citations
Medicine, Cardiology, Surgery +14