Safety of <sup>125</sup>iodine and <sup>192</sup>iridium implants to the canine carotid artery: Preliminary report

18

Citations

13

References

1985

Year

Abstract

Thirty-nine healthy dogs underwent a simulated radical neck dissection followed by implantation of either 125Iodine (125I) or 192Iridium (192Ir) in various dose regimes randomized prospectively from 3,000 to 30,000 rad. Bilateral selective carotid angiography was performed immediately postoperatively and at six months and one year. No significant effects occurred to the animals who received 15,000 rad 125I or 6,000 rad 192Ir. In the higher dosed animals the 125I treated group fared better than the 192Ir treated group, probably due to the lower dose rate delivery. All surviving animals will be maintained an additional year to determine the late effects of brachytherapy irradiation to the carotid artery.