Strategies for selecting Recombinant CHO cell lines for cGMP manufacturing: Realizing the potential in bioreactors

Alison Porter, Alan J. Dickson, Andrew J. Racher

Biotechnology Progress · 2010 · 51 citations · 31 references

TL;DR

Manufacturing recombinant proteins from mammalian cell lines requires large bioreactors, but their cost and complexity limit their use, so small‑scale shake‑flask models are commonly employed to select cell lines for subsequent bioreactor evaluation. The study aims to evaluate whether shake‑flask performance predicts bioreactor behavior and to discuss ways to improve the predictability of cell line selection. The authors assessed 29 GS‑CHO antibody‑producing cell lines, selected from 175 transfectants, in 10‑L bioreactors to compare growth, productivity, and metabolite utilization with prior shake‑flask data. The 10‑L bioreactor assessment showed wide variation in growth, productivity, and metabolite use, with high‑producing lines largely matching shake‑flask rankings but some rank shifts observed. © 2010 American Institute of Chemical Engineers, Biotechnol.

Abstract

Abstract Manufacture of recombinant proteins from mammalian cell lines requires the use of bioreactor systems at scales of up to 20,000 L. The cost and complexity of such systems can prohibit their extensive use during the process to construct and select the manufacturing cell line. It is therefore common practice to develop a model of the production process in a small scale vessel, such as a shake‐flask, where lower costs, ease of handling, and higher throughput are possible. This model can then be used to select a small number of cell lines for further evaluation in bioreactor culture. Here, we extend our previous work investigating cell line construction strategies to assess how well the behavior of cell lines in such a shake‐flask assessment predicts behavior in the associated bioreactor production process. A panel of 29 GS‐CHO cell lines, all producing the same antibody, were selected to include a mixture of high and low producers from a pool of 175 transfectants. Assessment of this panel in 10 L bioreactor culture revealed wide variation in parameters including growth, productivity, and metabolite utilization. In general, those cell lines which were high producing in the bioreactor cultures had also been higher producing in an earlier shake‐flask assessment. However, some changes in rank position of the evaluated cell lines were seen between the two systems. A potential explanation of these observations is discussed and approaches to improve the predictability of assessments used for cell line selection are considered. © 2010 American Institute of Chemical Engineers Biotechnol. Prog., 2010

References

31