Physics in Medicine and Biology · 2003 · 67 citations · 21 references
MedicineDermatologySurgeryDermatologic SurgeryHeat TransferThermal AnalysisHeat Transfer FundamentalsHeat Transfer ModelingLaser CoolingLaser SurgeryTemperature MeasurementTransient Heat TransferCutaneous Heat ExchangeDermatologic Laser TreatmentHeat Flux MeasurementHeat Transfer CoefficientsInverse Heat Conduction ProblemsSkin Temperature MeasurementSpray CoolingSurface Temperature
Although cryogen spray cooling (CSC) is used to minimize the risk of epidermal damage during laser dermatologic surgery, optimization of the current cooling approach is needed to permit the safe use of higher light doses, which should improve the therapeutic outcome in many patients. The objective of this study was to measure the effect of spurt duration (delta t) on the heat transfer dynamics during CSC using a model skin phantom. A fast-response temperature sensor was constructed to record the changes in surface temperature during CSC. Temperature measurements as a function of delta t at two nozzle-to-skin distances (z = 50 and 20 mm) were performed. The average surface heat fluxes (q) and heat transfer coefficients (h) for each delta t were computed using an inverse heat conduction problem algorithm. It was observed that q undergoes a marked dynamic variation during the entire delta t, with a maximum heat flux (qc) occurring early in the spurt (5-15 ms), followed by a quick decrease. The estimated qc vary from 450 to 600 kW m(-2), corresponding to h maxima of 10 and 17-22 kW m(-2) K(-1) for z = 50 and 20 mm, respectively. For z = 50 mm, spurts longer than 40 ms do not increase the total heat removal (Q) within the first 200 ms. However, for z = 20 mm, delta t longer than 100 ms are required to achieve the same Q. It is shown that the heat transfer dynamics and the time it takes to reach qc during CSC can be understood through classic boiling theory as a transition from transient to nucleate boiling. Based on the results of this model skin phantom, it is shown that spurts longer than 40 ms have a negligible impact on both q and Q within clinically relevant cooling times (10-100 ms).
21
Cryogen Spray Cooling in Combination With Nonablative Laser Treatment of Facial Rhytides
Kristen M. Kelly, J. Stuart Nelson, Gary Lask et al. · Archives of Dermatology · 1999 · 216 citations · Full text
Medicine, Dermatology, Surgery +17
Guillermo Aguilar, Boris Majaron, Wim Verkruysse et al. · International Journal of Heat and Mass Transfer · 2001 · 104 citations · Full text
Engineering, Chemical Engineering, Computational Heat Transfer +16