Publication | Closed Access
Diagnosis of meniscal tears of the knee with MR imaging: effect of observer variation and sample size on sensitivity and specificity.
48
Citations
16
References
1993
Year
We conclude that chance variation related to sample size can cause large but not statistically significant variations in sensitivity and specificity in this setting. These variations are of sufficient magnitude to explain many of the differences in reported sensitivity and specificity for MR imaging in the diagnosis of meniscal tears. We found no significant difference in observer performance.