PESC record · 2008 · 15 citations · 8 references
EngineeringElectrical EngineeringHeat TransferPower ElectronicsRenewable Energy SystemsConverter TopologiesDc-ac InvertersElectric Motor Drive SystemsLosses In Electric MachinesMultilevel ConvertersHarmonic DistortionHeat Sink DesignInduction Motor DrivesInverter SystemsInvertersMultilevel Inverter TopologiesMultilevel InvertersTotal Harmonic Distortion
This paper presents the comparison of three topologies of multilevel inverters applied to drive an induction motor of 500 kVA/4.16 kV. The multilevel inverters analyzed are: a neutral point clamped inverter, a symmetrical cascaded multilevel inverter and a hybrid asymmetrical cascaded multilevel inverter. The performance indexes used in the comparison are total harmonic distortion, first order distortion factor, semiconductors power losses distribution and heat-sink volume. The comparison is developed with the purpose of finding the efficiency and the heat-sink volume where the three systems present the same output filter.
8
The analysis of conduction and switching losses in multi-level inverter system
Taejin Kim, Dae-Wook Kang, Yohan Lee et al. · 2002 · 117 citations