IEEE Transactions on Applied Superconductivity · 2006 · 16 citations · 6 references
EngineeringElectrical EngineeringPhysicsCircuit TheoryHeat TransferPower ElectronicsElectrical System DiagnosticsLoss Distribution AnalysisLosses In Electric MachinesPower QualityAc LossesCore Loss AnalysisCore Loss ModelingCore LossesLoss AnalysisMagnetic Loss CharacterizationPower Loss EstimationPulse Characteristics
The KSTAR Central Solenoid Model Coils (CSMC), which are in the form of split coils with same dimension, have been tested. The CSMC were successfully charged up to 20 kA and down to zero with different ramp rates. Various pulse waveforms were applied to the CSMC to analyse the AC-loss characteristics of the coils. The measurement method was a gas-flow calorimetry. In this work, two types of waveforms, the DC-biased sinusoidal wave ( <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$I_dc = 2$</tex> , 4 kA; <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$mitDeltaI_ac = 1 kA$</tex> ; <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$f = 0.08sim 0.67 Hz$</tex> ) and a single triangular pulse ( <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$I_max = 6sim10 kA$</tex> ; <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$dI/dt = 0.5sim 2 kA/s$</tex> ), are selected and analysed. From the measured data at the one outlet where helium channel 3 and 4 are merged, the AC loss parameters, related with the hysteresis loss and the coupling loss, are calculated. The B-field strength differs depending on the position within the cooling channels. The spatial field variation and the ramp rate were 0.048 <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$sim$</tex> 1.9 T and 8.1 <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$sim$</tex> 71 mT/s for the DC-biased sinusoidal waves, while 0.29 <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$sim$</tex> 4.3 T and 0.024 <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$sim$</tex> 0.86 T/s for the triangular pulses. The measured AC losses are compared with estimated values and the behavior agrees well. The coupling time constant <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$(ntau)$</tex> varies with the field strength. In case of the triangular pulses, <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$ntau$</tex> increases by increasing the field amplitude and the maximum value of <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$ntau$</tex> is 41 ms with <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$I_max = 10 kA$</tex> .
6
Arend Nijhuis, N.H.W. Noordman, Herman H.J. ten Kate et al. · IEEE Transactions on Applied Superconductivity · 1999 · 37 citations · Full text
Arend Nijhuis, N.H.W. Noordman, Herman H.J. ten Kate et al. · IEEE Transactions on Applied Superconductivity · 1999 · 35 citations
Engineering, Electrical Engineering, Mechanical Engineering +16
Fabrication of the KSTAR superconducting CICC
Byung Su Lim, S.I. Lee, K.M. Kim et al. · IEEE Transactions on Applied Superconductivity · 2002 · 19 citations