International Journal of Environmental & Analytical Chemistry · 1983 · 19 citations · 16 references
Natural SciencesChemistryToxicologyAnalytical ChemistryAnalytical ToxicologySeparation ScienceEnvironmental AnalysisEnvironmental Analytical ChemistryVolatile Organic CompoundsVolatile Substance AnalysisWater PollutionAnalytical Detection Of Organic PollutantsAutomated Sample PreparationAzeotropic DistillationEnvironmental Sample PreparationIsolationSample Preparation Method DevelopmentVolatile Organic Compound AnalysisVolatile Organic Compounds Analysis
Abstract In most investigations on water quality it is not possible to determine the relationship between toxicological and chemical parameters as a consequence of different isolation and sample preparation techniques. A combined research made by the analytical-chemical and biological section of KIWA has led to the development of a single isolation and sample preparation method for organic micro-pollutants in water, suitable for both toxicological and chemical measurements as the Ames test, group parameters (OCI, ON, OS, OP), GC-MS and H.P.L.C. An automated installation for the adsorption of volatiles to Tenax and of slightly-volatile and non-volatile compounds at pH 7,2 and 9 to XAD-4 has been built. Following the adsorption the volatiles are thermically desorbed from the Tenax. The XAD columns are eluted with ethanol and an ethanol-cyclohexane mixture. The eluates are dried and concentrated by means of an azeotropic distillation. This procedure has been automated as well.
16