BMC Pulmonary Medicine · 2015 · 23 citations · 24 references
MedicineNuclear MedicineOncologyDiagnostic RadiologyMetastasisThoracic ImagingComputed TomographyLung CancerLymph Node MetastasisPositron Emission TomographyThoracic Oncology ImagingTumor CharacterizationLung Cancer Metastasis To Lymph NodesLymph Node MetastasesLymph Node Size AssessmentMetastatic Lymph Node BurdenNon-small Cell Lung Cancer ImagingPet-computed TomographyPositron Emission Tomography DiagnosisSquamous Cell Carcinoma Histology
BACKGROUND: To evaluate the factors affecting the maximum standardized uptake value (SUVmax) of metastatic lymph nodes in different histological types of non-small cell lung cancer (NSCLC) on integrated positron emission tomography and computed tomography (PET-CT). METHODS: This was a retrospective, single-institution review of 122 patients with pathologically proven NSCLC who had PET-CT scanning at the same center. Lymph node metastases were pathologically confirmed in tissue specimens from surgical patients. Statistical evaluation of PET-CT results was performed on a per-nodal-station basis. RESULTS: The tumor SUVmax of squamous cell carcinoma (SCC) (11.0 ± 4.1) was higher than that of adenocarcinoma (AC) (7.4 ± 4.4) (P < 0.01), however, the SUVmax of the metastatic lymph nodes did not differ between the SCC (4.6 ± 3.1) and AC groups(3.6 ± 2.5) (P = 0.221). The SUVmax of metastatic lymph nodes was positively correlated with lymph node size but not with the primary tumor SUVmax, primary tumor size, tumor location and tumor differentiation. The frequency of a SUVmax of lymph nodes ≥2.5 was 44%, 80%,100% in SCC group and 39%, 59%, 90% in AC group when the short-axis diameter of metastatic lymph node was <10 mm, 10-15 mm, and > 15 mm, respectively. The low sensitivity for metastatic lymph nodes on PET-CT was increased when the SUVmax cut-off for malignancy was considered to be above the normal background compared with that when the SUVmax cut-off was above 2.5. CONCLUSIONS: There was no difference in the SUVmax of metastatic lymph nodes in the SCC and AC groups. The SUVmax of metastatic lymph nodes was positively correlated with metastatic lymph node size. There was a high false negative rate if lymph nodes with a short-axis diameter less than 10 mm and a extremely low false negative rate if lymph nodes with a short-axis diameter higher than 15 mm. Although an increased sensitivity may be achieved by decreasing the SUVmax cut-off, invasive staging may still be required for negative lymph nodes due to the lower sensitivity of PET-CT in both SCC and AC.
24
Ahmedin Jemal, Freddie Bray, Jacques Ferlay et al. · CA A Cancer Journal for Clinicians · 2011 · 55K citations · Full text
Global Cancer Statistics, 2002
Donald Maxwell Parkin, Freddie Bray, Jacques Ferlay et al. · CA A Cancer Journal for Clinicians · 2005 · 18.4K citations · Full text
Pepijn Brocken, P.N.R. Dekhuijzen, Liesbeth Peters-Bax et al. · Respiration · 2013 · 4K citations · Full text
Preoperative Staging of Lung Cancer with Combined PET–CT
Barbara Malene Fischer, Ulrik Lassen, Jann Mortensen et al. · New England Journal of Medicine · 2009 · 583 citations · Full text