Current Eye Research · 2010 · 53 citations · 17 references
MedicineOphthalmologySurgeryClinical OptometryOphthalmic SurgeryRefractive SurgeryAstigmatism CorrectionHigh MyopiaOcular BiometryPreoperative Refractive EvaluationRefractive ErrorRefractive Error AssessmentOcular Surface Wavefront ImagingPostoperative AstigmatismPupil DiameterRefractive AstigmatismRefractive Cataract SurgeryRefractive Surgery AssessmentSpherical Equivalent RefractionSurgical Astigmatism
PURPOSE: To identify factors which affect mesopic pupil diameter in refractive surgery patients. SETTING: This retrospective study was performed at the 1st Ophthalmology Clinic in Ankara Ataturk Training and Research Hospital, Ankara, Turkey. METHODS: Medical records of 412 refractive surgery candidates who applied between 2006 and 2008 were reviewed. Detailed ophthalmological examination data were obtained from medical records. Pupil size measurements were performed with a COAS Ocular Wavefront analyzer in mesopic conditions. Relationship between mesopic pupil diameter and age, sex, spherical refractive error (D), magnitude of astigmatism (D), type of astigmatism, spherical equivalent, and average keratometry were analyzed by means of univariate and multivariate regression analyses. RESULTS: Mean mesopic pupil diameter was 6.19 +/- 0.88 mm. Mean pupil diameter (mean +/- standard deviation) was 5.70 +/- 1.01 in hypermetropia, 6.04 +/- 0.79 mm in mixed astigmatism, and 6.33 +/- 0.82 mm in myopia. The difference in mean mesopic pupil diameters between myopes and hypermetropes was statistically significant (p = 0.001). However, differences with regard to mean pupil diameters between myopes and mixed astigmatism (p = 0.660) and between hypermetropes and mixed astigmatism (p = 0.109) were not significant. Mean pupil diameter was 6.00 +/- 0.99 mm in against the rule astigmatism, 5.96 +/- 0.84 mm in oblique astigmatism, and 6.27 +/- 0.84 mm in with the rule astigmatism. Mean mesopic pupil diameter in with the rule astigmatism group was higher than oblique astigmatism group. Spherical refractive error (r = -0.213, p = 0.001), cylindrical refractive error (0.197, p = 0.001), and age (r = -0.341, p = 0.001) showed correlation with pupil diameter. CONCLUSIONS: This study showed that age and magnitude of both spherical and cylindrical refractive error are the most determinative factors on mesopic pupil size.
17
Factors affecting light-adapted pupil size in normal human subjects.
Barry Winn, David Whitaker, David B. Elliott et al. · PubMed · 1994 · 694 citations
Centering Corneal Surgical Procedures
Hiroshi Uozato, David L. Guyton · American Journal of Ophthalmology · 1987 · 292 citations
Medicine, Ophthalmology, Surgery +4
Risk factors for night vision complaints after LASIK for myopia
Mihai Pop, Yves Payette · Ophthalmology · 2004 · 179 citations · Full text
Pupil size and quality of vision after LASIK
Steven C. Schallhorn, Sandor E. Kaupp, David J. Tanzer et al. · Ophthalmology · 2003 · 157 citations