Optics Express · 2006 · 207 citations · 14 references
Natural SciencesBiomedical EngineeringBiomedical OpticsBiophotonicsOpticsFourier OpticsOptical CoherenceOptical Coherence TomographyOptical ImagingOptical TomographyUltrafast OpticsAxial ResolutionDispersive MediaFourier-domain Optical Coherence TomographyFourier-domain Signal ProcessingGroup-velocity DispersionHigh-speed ImagingSpectral-domain Optical Coherence TomographySupercontinuum Generation
We introduce a new high-speed Fourier-domain optical coherence tomography (FD-OCT) scheme based on a stretched pulse supercontinuum source. A wide-band short pulse of a supercontinuum source of which output spectrum spanned a wavelength range from 1,200 nm to 1,550 nm was stretched to a long pulse of 70-ns duration by using a dispersive fiber due to the group-velocity dispersion, and it was used directly as frequency-swept light for FD-OCT. The OCT spectral interferogram was acquired in the time domain and converted into the spectral domain by the pre-calibrated time-to-wavelength relation. Using this stretched-pulse OCT (SP-OCT) scheme, we have demonstrated an ultrahigh-speed axial-line scanning rate of 5 MHz. The axial resolution of 8 microm was achieved without re-calibration of the sweep characteristic owing to the passive nature of the frequency-sweeping mechanism.
14
David Huang, Eric A. Swanson, Charles P. Lin et al. · Science · 1991 · 13.7K citations
High-speed optical frequency-domain imaging
Seok‐Hyun Yun, G. J. Tearney, Johannes F. de Boer et al. · Optics Express · 2003 · 862 citations · Full text