PubMed · 2007 · 100 citations · 26 references
Open access
MedicineNeurological SurgeryRadiologyDiagnostic ImagingDiagnostic RadiologyNeuroradiologyBrain ImagingDiffusion ImagingImaging AnatomyMagnetic Resonance ImagingMedical ImagingMedical Imaging PhysicsDiffusion Magnetic Resonance ImagingDiffusion Tensor Imaging MarkersDiffusion Tractography In NeuroradiologyEcho Planar ImagingOccipital CortexOptic RadiationOptic TractWhite Matter Tractography
BACKGROUND AND PURPOSE: Knowing the exact location of the optic radiation preoperatively is important for surgery of the temporal lobe. We hypothesized that a greater number of motion-probing gradients (MPGs) would provide better results of diffusion tensor (DT) fiber tractography of the optic radiation. To test this hypothesis, this study evaluated differences in DT fiber tractography of the optic radiation under different MPG settings. METHODS: DT images were obtained in 12 healthy volunteers (7 men, 5 women) with a mean age of 32 years (range, 22-45 years) by using a 3T MR imaging scanner with single-shot echo-planar imaging with parallel acquisition (reduction factor = 2). MPG was applied in 6, 12, 40, and 81 independent directions. The first region of interest (ROI) was placed in the occipital lobe, and the second ROI was placed in the lateral geniculate body. Fibers penetrating both ROIs were considered as the optic radiation. Anteroposterior distance between the tip of the Meyer loop and the lateral geniculate body on an axial section was defined as a loop index. Numbers of fibers and loop indices in both cerebral hemispheres were evaluated statistically. RESULTS: The optic radiation was well visualized in full length by DT fiber tractography in 20 of 24 hemispheres (83%). No significant differences were noted in number of fibers and loop indices among different MPG settings. CONCLUSION: DT fiber tractography can frequently depict almost the entire optic radiation. MPG number does not exert any significant effect on visualization of the optic radiation, and 6-directional MPG is thus sufficient for this purpose.
26
MR diffusion tensor spectroscopy and imaging
Peter J. Basser, James Mattiello, D. LeBihan · Biophysical Journal · 1994 · 6K citations · Full text
Medicine, Neuroscience, Radiology +12
Three-dimensional tracking of axonal projections in the brain by magnetic resonance imaging
Susumu Mori, Barbara J. Crain, V. P. Chacko et al. · Annals of Neurology · 1999 · 3.5K citations
Medicine, Neurobiology, Neuroscience +16
Diffusion tensor MR imaging of the human brain.
Carlo Pierpaoli, Peter Jezzard, Peter J. Basser et al. · Radiology · 1996 · 2.7K citations
Medicine, Neuroscience, Radiology +17
Fiber Tract–based Atlas of Human White Matter Anatomy
Setsu Wakana, Lidia M. Nagae‐Poetscher, Peter C.M. van Zijl · Radiology · 2004 · 2K citations
Medicine, Anatomy, Neuroscience +17