Automated 3-D Intraretinal Layer Segmentation of Macular Spectral-Domain Optical Coherence Tomography Images
619
Citations
22
References
2009
Year
EngineeringSimultaneous SegmentationImage AnalysisBiomedical OpticEdge DetectionComputational GeometryGraph Segmentation MethodRadiologyGeometric ModelingMachine VisionMedical ImagingOphthalmologyMedical Image ComputingOptical ImagingComputer Vision3-D Segmentation MethodsNatural SciencesBiomedical ImagingOptical Coherence TomographyMedical Image AnalysisImage Segmentation3D Imaging
Spectral‑domain OCT produces much larger image datasets than time‑domain OCT, creating an increasing need for 3‑D segmentation methods. The authors present a graph‑theoretic method that simultaneously segments multiple 3‑D surfaces and is guaranteed to be optimal with respect to the cost function. The method incorporates learned feasibility constraints and regional information from a training set of 13 images and was evaluated on a test set of 28 images from 14 subjects. It achieved an overall mean unsigned border positioning error of 5.69 ± 2.41 µm for seven surfaces, comparable to the interobserver variability of 5.71 ± 1.98 µm.
With the introduction of spectral-domain optical coherence tomography (OCT), much larger image datasets are routinely acquired compared to what was possible using the previous generation of time-domain OCT. Thus, the need for 3-D segmentation methods for processing such data is becoming increasingly important. We report a graph-theoretic segmentation method for the simultaneous segmentation of multiple 3-D surfaces that is guaranteed to be optimal with respect to the cost function and that is directly applicable to the segmentation of 3-D spectral OCT image data. We present two extensions to the general layered graph segmentation method: the ability to incorporate varying feasibility constraints and the ability to incorporate true regional information. Appropriate feasibility constraints and cost functions were learned from a training set of 13 spectral-domain OCT images from 13 subjects. After training, our approach was tested on a test set of 28 images from 14 subjects. An overall mean unsigned border positioning error of 5.69+/-2.41 microm was achieved when segmenting seven surfaces (six layers) and using the average of the manual tracings of two ophthalmologists as the reference standard. This result is very comparable to the measured interobserver variability of 5.71+/-1.98 microm.
| Year | Citations | |
|---|---|---|
Page 1
Page 1