2004 IEEE 35th Annual Power Electronics Specialists Conference (IEEE Cat. No.04CH37551) · 2004 · 54 citations · 9 references
EngineeringElectrical EngineeringCircuit TheoryElectric MachinesPower ElectronicsFault DetectionInduction MachinesMachine WindingsPower Electronics For Renewable EnergyWind Energy SystemsWind Turbine TechnologyFault AnalysisIncipient Fault DetectionModel SimulationPhase AngleShort-circuit CurrentShort-circuit Fault DetectionStator Winding FaultsStator Windings
The doubly fed induction generator (DFIG) is an important component of wind turbine systems. It is necessary to identify incipient faults quickly. This paper proposes a complete simulation model of DFIG in wind turbine about inter-turn short circuit fault at stator windings, which is based on multi-circuit theory. A detail analysis about simulation results is presented, especially about short circuit current. By analysis, the apparent 150 Hz, 450 Hz and current phase angle difference are taken as fault features and the fault phase also can be detected by phase angle difference. Both simulated results and experimental results of emulated inter-turn short circuit fault by paralleling a resistance with phase A are carried out. They verify the preceding analysis results. Moreover, their coincidence certificates this model is good and simulation results of inter-turn short circuit fault are correct.
9
Multiple coupled circuit modeling of induction machines
Xin Luo, Yuefeng Liao, Hamid A. Toliyat et al. · 2002 · 298 citations