American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · 2013 · 15 citations · 29 references
Life SciencesPhysiologyVeterinary PhysiologyElectrophysiologyHemodynamic ManagementPhysiological Systems ModelingAutonomic Nervous SystemCardiovascular MonitoringDiving PhysiologyElectrocardiographySwine PhysiologyAutonomic Nervous System ChangesAutonomic Nervous System EffectsCardiovascular Responses To DivingHeart RateHeart Rate MeasurementPower Spectral DensityPower Spectral Density AnalysisSympathetic Nervous System Modulation
Methods to predict onset of cardiopulmonary (CP) decompression sickness (DCS) would be of great benefit to clinicians caring for stricken divers. Principal dynamic mode (PDM) analysis of the electrocardiogram has been shown to provide accurate separation of the sympathetic and parasympathetic tone dynamics. Nine swine (Sus scrofa) underwent a 15-h saturation dive at 184 kPa (60 ft. of saltwater) in a hyperbaric chamber followed by dropout decompression, whereas six swine, used as a control, underwent a 15-h saturation dive at 15 kPa (5 ft. of saltwater). Noninvasive electrocardiograms were recorded throughout the experiment and autonomic nervous system dynamics were evaluated by heart rate series analysis using power spectral density (PSD) and PDM methods. We observed a significant increase in the sympathetic and parasympathetic tones using the PDM method on average 20 min before DCS onset following a sudden induction of decompression. Parasympathetic activities remained elevated, but the sympathetic modulation was significantly reduced at onset of cutis and CP DCS signs, as reported by a trained observer. Similar nonsignificant observations occurred during PSD analysis. PDM observations contrast with previous work showing that neurological DCS resulted in a >50% reduction in both sympathetic and parasympathetic tone. Therefore, tracking dynamics of the parasympathetic tones via the PDM method may allow discrimination between CP DCS and neurological DCS, and this significant increase in parasympathetic tone has potential use as a marker for early diagnosis of CP DCS.
29
Task Force of the European Society of Cardiology the North A Electrophysiology · Circulation · 1996 · 16.9K citations
Heart rate variability: Standards of measurement, physiological interpretation, and clinical use
Marek Malik, J. Thomas Bigger, A. John Camm et al. · European Heart Journal · 1996 · 15.3K citations · Full text
Nursing, Cardiology, Physiology +15
An Efficient Algorithm for Spectral Analysis of Heart Rate Variability
Ronald D. Berger, S. Akselrod, David Gordon et al. · IEEE Transactions on Biomedical Engineering · 1986 · 818 citations
Medicine, Cardiology, Physiology +16