Separation Science and Technology · 2008 · 46 citations · 14 references
EngineeringChemical EngineeringComputational Fluid DynamicsFluid DynamicsSeparation ProcessesParticle-laden FlowsTurbulenceTurbulent FlowCfd SimulationComputational Fluid Dynamics Of SeparationCut-sizeHydrocyclone SeparationHydrocyclonesParticle Size SeparationSeparation EfficiencyVelocity Profiles
Abstract Effects of geometric structure parameters of 10 mm-diameter hydrocyclones on the particle separation efficiency are studied using computational fluid dynamics (CFD). The fluid velocity profiles and particle trajectories are simulated using RFLOW software with a standard isotropic k-ε turbulent model. The JIS standard CaCO3-17 particles are adopted as a particulate sample in simulations and experiments. Comparing the simulated results with experimental data, a maximum deviation about 20% in partition curves occurs for 5–10 µm particles. However, fairly good agreements for the cut-size predictions and the fish-hook phenomenon are obtained. The simulated cut-size d 50 is only 2 µm larger than that measured in experiments, while the value of d 100 can be accurately predicted. An increase in overflow diameter or a decrease in underflow diameter leads to a lower separation efficiency but a clearer separation sharpness due to lower fluid underflow rate. A short-and-wide rectangular inlet is more efficient for particle separation than a tall-and-narrow one. An inclined inlet conduit plays an inessential role on the efficiency improvement but gains a 2 µm reduction in d 100. Comparing the simulated results, the hydrocyclone used in the experiments of this study exhibits a higher separation sharpness than the Rietema type and a higher efficiency than the Bradley type based on the same operation capacity and hydrocyclone size.
14
CFD simulation and experimental validation studies on hydrocyclone
K. Bhaskar, Y. Rama Murthy, Martin Raju et al. · Minerals Engineering · 2006 · 200 citations
Engineering, Aerospace Engineering, Chemical Engineering +13