Journal of Contemporary Brachytherapy · 2013 · 63 citations · 29 references
MedicineOncologyRadiation OncologyBiomedical ImagingRadiation DosimetryTreatment PlanningBrachytherapy DosimetryBrachytherapy For Gynecologic MalignanciesBrachytherapy PhysicsImage-guided RadiotherapyImage-guided TherapyRadiation TherapyApplicator PlacementApplicator ReconstructionCervical Cancer BrachytherapyCervical Cancer RadiotherapyImage-guided BrachytherapyThree-dimensional Dose Reconstruction
PURPOSE: To quantify the dosimetric impact of applicator displacements and applicator reconstruction-uncertainties through simulated planning studies of virtual applicator shifts. MATERIAL AND METHODS: Twenty randomly selected high-dose-rate (HDR) titanium tandem-and-ovoid (T&O) plans were retrospectively studied. MRI-guided, conformal brachytherapy (MRIG-CBT) plans were retrospectively generated. To simulate T&O displacement, the whole T&O set was virtually shifted on treatment planning system in the cranial (+) and the caudal (-) direction after each dose calculation. Each shifted plan was compared to an unshifted plan. To simulate T&O reconstruction-uncertainties, each tandem and ovoid was separately shifted along its axis before performing the dose calculation. After the dose calculation, the calculated isodose lines and T&O were moved back to unshifted T&O position. Shifted and shifted-back plan were compared. RESULTS: Regarding the dosimetric impact of the simulated T&O displacements, rectal D2cc values were observed as being the most sensitive to change due to T&O displacement among all dosimetric metrics regardless of point A (p < 0.013) or MRIG-CBT plans (p < 0.0277). To avoid more than 10% change, ± 1.5 mm T&O displacements were accommodated for both point A and MRIG-CBT plans. The dosimetric impact of T&O displacements on sigmoid (p < 0.0005), bladder (p < 0.0001), HR-CTV (p < 0.0036), and point A (p < 0.0015) were significantly larger in the MRIG-CBT plans than point A plans. Regarding the dosimetric impact of T&O reconstruction-uncertainties, less than ± 3.0 mm reconstruction-uncertainties were also required in order to avoid more than 10% dosimetric change in either the point A or MRIG-CBT plans. CONCLUSIONS: The dosimetric impact of simulated T&O displacements was significantly larger in the MRIG-CBT plans than in the point A plans. Either ± 3 mm T&O displacement or a ± 4.5 mm T&O reconstruction-uncertainty could cause greater than 10% dosimetric change for both point A plans and MRIG-CBT plans.
29
Richard Pötter, Christine Haie-Méder, Erik Van Limbergen et al. · Radiotherapy and Oncology · 2006 · 1.6K citations
Medicine, Gynecology, Oncology +17
Akila N. Viswanathan, Johannes Dimopoulos, Daniel Berger et al. · International Journal of Radiation Oncology*Biology*Physics · 2007 · 458 citations
Taran Paulsen Hellebust, Christian Kirisits, Daniel Berger et al. · Radiotherapy and Oncology · 2010 · 321 citations