Journal of Nuclear Medicine · 2009 · 49 citations · 17 references
MedicineNuclear MedicineRadiologyDiagnostic RadiologyThoracic ImagingThoracic OncologyComputed TomographyDeep Inspiration Breath HoldLung CancerPositron Emission TomographyThoracic Oncology ImagingClinical Protocol DesignLung Tumor ImagingOncologic Pet ImagingPet-computed Tomography
UNLABELLED: This study was designed to compare tumor (18)F-FDG uptake between a single 20-s acquisition of deep-inspiration breath-hold PET/CT and free-breathing PET/CT for lung cancer. METHODS: Before the clinical study, a phantom study was performed to determine the optimum breath-hold time for the PET scan. We studied 47 patients with lung cancer who underwent free-breathing PET/CT with the standard clinical protocol, followed by deep-inspiration breath-hold PET/CT of the thorax. In breath-hold PET/CT, the patients were asked to hold their breath in deep inspiration for 10 s during the CT scan and for 20 s during the PET scan. Maximum tumor (18)F-FDG standardized uptake value (SUVmax) was measured in free-breathing PET and breath-hold PET, and the percentage difference between these 2 values was calculated. RESULTS: Breath-hold PET showed a significant increase in SUVmax, as compared with free-breathing PET (8.26 +/- 4.59 vs. 11.25 +/- 7.24, P < 0.0001). The mean difference in SUVmax was 39.5% +/- 43.4%, and the range was 2.9%-248.3%. The difference in SUVmax was significant when compared between tumors in the upper lung (n = 22) and tumors in the lower lung (n = 25) (24.4% +/- 17.7% vs. 52.9% +/- 54.3%, P = 0.0077). The mean tumor size of the group with a high SUVmax difference (n = 13) was significantly smaller than that of the group with a low SUVmax difference (n = 34) (2.45 +/- 0.87 cm vs. 3.21 +/- 1.22 cm, P = 0.043), using a cutoff of 39.5%. CONCLUSION: The single 20-s acquisition of breath-hold PET/CT enabled more precise measurement of SUVmax, especially in the lower lung field and for small tumors, which may be affected by respiratory motion. This technique is feasible in the clinical setting and requires only a minor increase in examination time.
17
Four‐dimensional (4D) PET/CT imaging of the thorax
Sadek A. Nehmeh, Yusuf E. Erdi, Tinsu Pan et al. · Medical Physics · 2004 · 348 citations
The CT motion quantitation of lung lesions and its impact on PET-measured SUVs.
Yusuf E. Erdi, Sadek A. Nehmeh, Tinsu Pan et al. · PubMed · 2004 · 283 citations
Clinically significant inaccurate localization of lesions with PET/CT: frequency in 300 patients.
Medhat Osman, Christian Cohade, Yuji Nakamoto et al. · PubMed · 2003 · 252 citations
Attenuation correction of PET images with respiration-averaged CT images in PET/CT.
Tinsu Pan, Osama Mawlawi, Sadek A. Nehmeh et al. · PubMed · 2005 · 251 citations
Quantitation of respiratory motion during 4D‐PET/CT acquisition
S. A. Nehmeh, Yusuf E. Erdi, Tin-Su Pan et al. · Medical Physics · 2004 · 232 citations