A study on the use of lead fluoride for electromagnetic calorimetry

C. Woody, J.A. Kierstead, P. W. Levy, S. P. Stoll, A.B. Weingarten, D.F. Anderson, E. J. Ramberg, Yusuke Kuno, J. A. Macdonald, A. Konaka,

IEEE Transactions on Nuclear Science · 1993 · 23 citations · 4 references

Concepts

Abstract

The properties of lead fluoride as a Cerenkov material for use in electromagnetic calorimetry were studied. A prototype calorimeter module consisting of a 5*5 array of 2.1-cm*2.1-cm*18.5-cm crystals was built and tested in a test beam. Results are given on energy resolution, shower size, and e/ pi separation for electrons and pions in the range of 1-4 GeV. The light output was found to give >or=1000 photoelectrons per MeV in good quality crystals and to provide useful signals down to as low as 32 MeV. Measurements were made on radiation damage in lead fluoride using /sup 60/Co gamma rays and high energy ionizing particles, as well as on thermoluminescence after irradiation. It was found that only modest damage occurs up to a level of approximately 30 krad in large, calorimeter size crystals, and that the damage can be easily removed by optical bleaching.< <ETX xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">&gt;</ETX>

References

4