IEEE Transactions on Instrumentation and Measurement · 2007 · 63 citations · 5 references
EngineeringElectrical EngineeringInstrumentationMetrologyUncertainty QuantificationCurrent Measurement InstrumentsElectrical MeasurementElectrical MetrologyMeasurement ErrorMeasurement StandardsMeasurement UncertaintyCurrent MeasurementCurrent Measurement AccuracyElectrical Measurement Error AnalysisMeasurement TechniquesPhase AnglePrecision MeasurementShunt MeasurementUncertainty In Angle Measurement
This paper describes the measurement techniques and results of the determination of phase angle errors of a set of National Measurement Institute, Australia, precision current shunts, rated from 100 mA to 20 A, in the frequency range from 40 Hz to 200 kHz. The standard uncertainties of the determination range from 1.3 murad at low frequencies to less than 150 murad at 200 kHz
5
Calibration of 1000 V/50 Hz Inductive Voltage Dividers and Ratio Transformers
Ilya Budovsky, G.W. Small, A.M. Gibbes et al. · 2004 · 21 citations