Publication | Open Access
Hemodynamics in a cerebral artery before and after the formation of an aneurysm.
194
Citations
12
References
2006
Year
HemodynamicsEngineeringFluid MechanicsVascular MalformationBiomedical EngineeringComputational MechanicsCerebral Vascular RegulationNeurovascular DiseaseBlood FlowParent ArteryVirtual RemovalBiomechanicsVascular SurgeryNeurologyBlood Flow MeasurementRadiologyCardiovascular ImagingGeometric ModelingParaclinoid AneurysmsVascular ImageMedical ImagingMedicineCerebral Blood FlowBiomedical FlowDigital Subtraction AngiographyCerebral ArteryNeuroscienceStrokeAnesthesiology
Using data obtained from 3D digital subtraction angiography acquisitions, computational fluid dynamics techniques were used first to assess hemodynamic factors in geometrically correct models of 3 paraclinoid aneurysms and then again for assessment after virtual removal of the aneurysms and reconstruction of the parent artery. Simulations revealed an area of relatively low and rotating wall shear stresses at the location at which each aneurysm had developed. This phenomenon, to our knowledge, has not been previously described.
| Year | Citations | |
|---|---|---|
Page 1