IEEE Transactions on Industrial Electronics · 2008 · 97 citations · 21 references
EngineeringElectrical EngineeringElectric MachinesElectromagneticsMachine DesignElectric DrivesElectric MotorsElectromagnetic Torque ProductionLosses In Electric MachinesMagnetic Circuit AnalysisPermanent Magnet MachinesCore Loss AnalysisCore Loss ModelingElectrohydraulic SystemsInterior Permanent Magnet Synchronous MachinesMagnetic Equivalent CircuitsMagnetic SaturationMagnetic Saturation AnalysisMagnetic Saturation Effects
This paper presents design and analysis results of a 2.6-kW interior permanent-magnet synchronous motor developed for an electrohydraulic power steering system. The motor was designed by using the proposed equivalent magnetic circuit model in consideration with a core loss. To analyze motor characteristics by using the equivalent magnetic circuit model, inductance and iron-loss resistance, which are affected critically by magnetic saturation, are obtained by using finite-element analysis. Finally, motor characteristics such as armature current, torque, and efficiency are calculated by the equivalent magnetic circuit model and verified by experimental results.
21