Publication | Closed Access
Shaft current in AC induction machine: an on line monitoring system and prediction rules
20
Citations
11
References
2002
Year
Unknown Venue
Fault DiagnosisElectric MachineEngineeringIndustrial EngineeringMotor DriveCondition MonitoringAc Induction MachineElectrical DriveSystems EngineeringLine Monitoring SystemElectrical EngineeringSlot HarmonicsOil FilmMechatronicsStructural Health MonitoringAutomatic Fault DetectionPrediction RulesAir Gap EccentricityIndustrial InformaticsFault Detection
This paper looks at a method of on-line shaft current monitoring system. Fault conditions such as air gap eccentricity, slot harmonics and rotor broken bars or end ring result in asymmetrical flux pattern around the shaft, hence resulting in shaft voltage. Bearing failures can occur when the voltage level exceeds the threshold of the oil film. The importance of the oil film is described. The proposed method of shaft current is noninvasive, reliable, portable and low cost. Causes of the shaft current are described and prediction rules introduced.
| Year | Citations | |
|---|---|---|
Page 1