Radiation Oncology · 2012 · 44 citations · 34 references
MedicineOncologyRadiation OncologyClinical Radiation OncologyRadiation DosimetryTreatment PlanningBladder CancerCancer Treatment PlanningIntensity-modulated RadiotherapyRadiation TherapyRadiation Treatment PlanningThree-dimensional Conformal Radiotherapy3D-conformal RadiotherapyBladder Cancer RadiotherapyMuscle-invasive Bladder Cancer TherapyRadiation Dose ConstraintsRadiotherapy Dose PlanningVolumetric Modulated Arc Therapy Dose PrescriptionVolumetric Modulated Arc Therapy DosimetryVolumetric Modulated Arc Therapy Planning
BACKGROUND: To compare 3 Dimensional Conformal radiotherapy (3D-CRT) with Intensity Modulated Radiotherapy (IMRT) with Volumetric-Modulated Arc Therapy (VMAT) for bladder cancer. METHODS: Radiotherapy plans for 15 patients with T2-T4N0M0 bladder cancer were prospectively developed for 3-DCRT, IMRT and VMAT using Varian Eclipse planning system. The same radiation therapist carried out all planning and the same clinical dosimetric constraints were used. 10 of the patients with well localised tumours had a simultaneous infield boost (SIB) of the primary tumour planned for both IMRT and VMAT. Tumour control probabilities and normal tissue complication probabilities were calculated. RESULTS: Mean planning time for 3D-CRT, IMRT and VMAT was 30.0, 49.3, and 141.0 minutes respectively. The mean PTV conformity (CI) index for 3D-CRT was 1.32, for IMRT 1.05, and for VMAT 1.05. The PTV Homogeneity (HI) index was 0.080 for 3D-CRT, 0.073 for IMRT and 0.086 for VMAT. Tumour control and normal tissue complication probabilities were similar for 3D-CRT, IMRT and VMAT. The mean monitor units were 267 (range 250-293) for 3D-CRT; 824 (range 641-1083) for IMRT; and 403 (range 333-489) for VMAT (P < 0.05). Average treatment delivery time were 2:25min (range 2:01-3:09) for 3D-CRT; 4:39 (range 3:41-6:40) for IMRT; and 1:14 (range 1:13-1:14) for VMAT. In selected patients, the SIB did not result in a higher dose to small bowel or rectum. CONCLUSIONS: VMAT is associated with similar dosimetric advantages as IMRT over 3D-CRT for muscle invasive bladder cancer. VMAT is associated with faster delivery times and less number of mean monitor units than IMRT. SIB is feasible in selected patients with localized tumours.
34
Volumetric modulated arc therapy: IMRT in a single gantry arc
Karl F. Otto · Medical Physics · 2007 · 1.9K citations · Full text
Medicine, Radiation Oncology, Clinical Radiation Oncology +16
David A. Palma, E. Vollans, Kerry James et al. · International Journal of Radiation Oncology*Biology*Physics · 2008 · 530 citations
Medicine, Radiation Oncology, Clinical Radiation Oncology +16