Journal of Thermophysics and Heat Transfer · 1993 · 19 citations · 21 references
Natural SciencesMaterials EngineeringMaterials ScienceHeat TransferMetallic MaterialsSurface ScienceCoatingsCondensationCondensation Heat TransferCondensation ProcessesPorous MaterialsSurface CoatingsAtmospheric PressureCondensation On Vertical SurfacesCondensing TechnologyExperimental Results InterpretationFilm CondensationHeat Flux MeasurementMetallic CoatingsNusselt Number
Condensation experiments are performed on vertical isothermal porous metallic-coated plates which are immersed in saturated steam containing noncondensable gas at atmospheric pressure. The experimental results of a porous-coated plate system demonstrate as much as a 200% increase in heat flux (represented by an average Nusselt number) as compared to the experimental data of a plain copper surface. A comparison of the experiments with a theoretical model based on porous/fluid composite condensation that has been previously published shows relative agreement. The results of this investigation highlight the potential that exists for enhanced condensation when a porous metallic coating is utilized.
21
Handbook of multiphase systems
H. Brenner · International Journal of Multiphase Flow · 1983 · 592 citations
D. B. Spalding · International Journal of Heat and Mass Transfer · 1969 · 351 citations
Applied Ocean Research · 1983 · 240 citations