An improved method for determining the DC magnetization curve using a ring specimen

T. Nakata, N. Takahashi, Koji Fujiwara, Masami Nakano, Yasuhiro Ogura, K. Matsubara

IEEE Transactions on Magnetics · 1992 · 20 citations · 0 references

DOIFull text

Open access

Concepts

Abstract

When the DC magnetization curve (B-H) of nonoriented material is measured in a ring specimen, there is an intrinsic error due to the assumption that the mean magnetic path length is equal to the mean geometric path length. A novel method for determining the B-H curve accurately is proposed. The validity of the method is verified by experiments.< <ETX xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">&gt;</ETX>