Circulation · 2002 · 354 citations · 19 references
MedicineCardiologySurgeryInterventional CardiologyUltrasonographyUltrasoundCoronary AngioplastyCoronary Artery DiseaseInterventional UltrasoundIntravascular ImagingPercutaneous Coronary InterventionStent PlacementBalloon-expandable StentsCoronary Lesion AssessmentIntraluminal ObstructionNeointimal Hyperplasia AssessmentPlaque Burden QuantificationPlaque QuantificationPullback ImagingStent Patency Assessment
BACKGROUND: The goal of this intravascular ultrasound investigation was to provide a more detailed morphological analysis of the local biological effects of the implantation of a sirolimus-eluting stent compared with an uncoated stent. METHODS AND RESULTS: In the RAVEL trial, 238 patients with single de novo lesions were randomized to receive either an 18-mm sirolimus-eluting stent (Bx VELOCITY stent, Cordis) or an uncoated stent (Bx VELOCITY stent). In a subset of 95 patients (sirolimus-eluting stent=48, uncoated stent=47), motorized intravascular ultrasound pullback (0.5 mm/s) was performed at a 6-month follow-up. Stent volumes, total vessel volumes, and plaque-behind-stent volumes were comparable. However, the difference in neointimal hyperplasia (2+/-5 versus 37+/-28 mm3) and percent of volume obstruction (1+/-3% versus 29+/-20%) at 6 months between the 2 groups was highly significant (P<0.001), emphasizing the nearly complete abolition of the proliferative process inside the drug-eluting stent. Analysis of the proximal and distal edge volumes showed no significant difference between the 2 groups in external elastic membrane or lumen and plaque volume at the proximal and distal edges. There was also no evidence of intrastent thrombosis or persisting dissection at the stent edges. Although there was a higher incidence of incomplete stent apposition in the sirolimus group compared with the uncoated stent group (P<0.05), it was not associated with any adverse clinical events at 1 year. CONCLUSIONS: Sirolimus-eluting stents are effective in preventing neointimal hyperplasia without creating edge effect and without affecting the plaque burden behind the struts.
19
Unstable angina. A classification.
Eugene Braunwald · Circulation · 1989 · 1.4K citations · Full text
Sustained Suppression of Neointimal Proliferation by Sirolimus-Eluting Stents
J. Eduardo Sousa, Marco A. Costa, Alexandre Abizaid et al. · Circulation · 2001 · 673 citations · Full text
Medicine, Cardiology, Surgery +10
Late Coronary Occlusion After Intracoronary Brachytherapy
Marco A. Costa, Manel Sabaté, Wim J. van der Giessen et al. · Circulation · 1999 · 390 citations · Full text
Medicine, Cardiology, Surgery +14
Predictors and outcomes of stent thrombosis. An intravascular ultrasound registry
N. Uren · European Heart Journal · 2002 · 295 citations
Medicine, Cardiology, Surgery +17