Pulmonary Embolism by Small Blood Clots: Physiological Responses in the Anaesthetized Dog

Robert J. Marshall, P. R. Allison

Thorax · 1962 · 27 citations · 8 references

DOIFull text

Open access

Concepts

Abstract

Embolization ofthepulmonary arteries of anaesthetized dogsbylarge blood clots orthrombi usually causes nodisturbance ofheart rhythmor ofrespiration atthetimeofimpaction ofthe embolus (Allison, Dunnill, andMarshall, 1960; Marshall, Allison, Sabiston, Bosman, andDunnill, inpreparation) andconsiderable recovery oflung function occurs during thefirst twoweeksafter theembolization. Itispossible thathuman pulmonary embolism ofsevere degree isdueto theimpaction ofalarge embolus after multiple small emboli havecaused aninitial partial obstructionofthepulmonary circulation. Experimental workinanimals alsosuggests thatembolism of small arteries, rather thanlarge arteries, initiates reflexes whichmay increase thepulmonary vascular resistance andcause evenmoreobstructiontothecirculation. Thepresent investigation wascarried outto observe therespiratory andhaemodynamic effects ofrepeated embolism bysmall bloodclots andthe recovery offunction after theembolization. METHODS The material usedforembolization in these experiments wasfresh bloodclot.Thedogswere premedicated withmorphine, 1.1mg/kg.,and chlorpromazine, 1.0mg./kg., andanaesthetized with pentobarbitone. The dogswerebledintosterile beakers, thebloodforeachinjection beingina separate beaker.Thebloodwasallowed tostand until ithadformed afirmclot whichwasthenchopped withsterile scissors, poured into asyringe, andinjected slowly intravenously. Insomeexperiments theblood wasinjected intotheforeleg veinthrough a thinwalled 18gaugeneedle andinothers itwasinjected through a polythene tubeinserted byway ofthe femoral veinintotheinferior venacava. Theinternal diameter ofbothneedle andtubewas1mm. Before theclots wereinjected thefunctional residual capacity (F.R.C.) anddiffusing capacity ofthelungs weremeasured (Marshall etal., inpreparation) and cardiac catheterization wascarried outtomeasurethe pulmonary arterial pressure. Inmostofthedogsthe catheter wasleft inthemainpulmonary artery during theinjection oftheclots. Cannulae wereinserted intotheleft femoral artery forrecording pressure, intotheright femoral artery forwithdrawing blood, intothesuperior venacavaformeasuring central venouspressure, andintotheright femoral veinfor theinjection ofdyeandbloodclots. A cuffed endotracheal tubewasinserted andrespiration was recorded using aspirometer andkymograph. Inmost oftheexperiments thedogsbreathed airenriched with oxygenbutintheexperiments wheretheright-to-left shunt wasmeasured (seebelow) thespirometer contained 100%oxygenandthedog's lungs werewashed outwithoxygenbefore connexion tothespirometer. An intra-oesophageal balloon connected toa capacitancemanometer wasusedtomeasureintrathoracic pressure, andtheoutput fromthis manometer, together witha volumetracing obtained froma lowtorque potentiometer attached to thespirometer, were

References

8