MedicineHematologyRadiologyDiagnostic ImagingDiagnostic RadiologyIron Metabolism DisordersHepatobiliary ImagingIron DeficiencyIron Deficiency DisordersIron MetabolismLiver ImagingMagnetic Resonance ImagingHepatic Iron AccumulationHepatic Iron Overload AssessmentLiver Iron Concentration AssessmentLiver Iron Concentration MeasurementMagnetic Resonance Imaging Iron QuantificationMagnetic Resonance Relaxation TimesRelaxation TimesT2 Relaxation
Iron deposits demonstrate characteristically shortened T2 relaxation times. Several previously published studies reported poor correlation between the in vivo hepatic 1/T2 measurements made by means of midfield magnetic resonance (MR) units and the hepatic iron content of iron-overloaded patients. In this study, the authors assessed the use of in vivo 1/T2 measurements obtained by means of MR imaging at 0.5 T using short echo times (13.4 and 30 msec) and single-echo-sequences as well as computed tomographic (CT) attenuation as a measure of liver iron concentration in 10 severely iron-overloaded patients with beta-thalassemia major. The iron concentrations in surgical wedge biopsy samples of the liver, which varied between 3 and 9 mg/g of wet weight (normal, less than or equal to 0.5 mg/g), correlated well (r = .93, P less than or equal to .0001) with the preoperative in vivo hepatic 1/T2 measurements. The CT attenuation did not correlate with liver iron concentration. Quantitative MR imaging is a readily available noninvasive method for the assessment of hepatic iron concentration in iron-overloaded patients, reducing the need for needle biopsies of the liver.