PubMed · 1988 · 12 citations · 4 references
MedicineNuclear MedicineRadiologyDiagnostic Nuclear MedicineDiagnostic RadiologyRadiation DosimetryLung DepositionPulmonary ImagingPulmonary Nuclear ImagingAlveolar DepositionGamma Camera ImagingLung Ventilation ImagingPulmonary Clearance MechanismsPulmonary ScintigraphyPulmonary Ventilation ImagingRadioaerosol Lung ScintigraphyTechnetium-99m Phosphate Imaging
Although [99mTc] diethylenetriaminepentaacetic acid (DTPA) is currently the most widely used radioaerosol, rapid alveolar clearance limits its usefulness for single photon emission computed tomography (SPECT) ventilation lung imaging. Previous research has shown that [99mTc]phosphate compounds have high alveolar deposition and slow clearance and thus provide suitable aerosols for pulmonary ventilation studies. We have compared the pulmonary retention and blood levels of [99mTc]pyrophosphate (PYP) and [99mTc]DTPA in eight normal nonsmoking male volunteers. These two radioaerosols have comparable pulmonary deposition. Technetium-99m PYP, however, has a much slower pulmonary clearance which allows sufficient time (20 or more minutes) for SPECT data acquisition using a single-headed rotating gamma camera. While the radiation absorbed dose to the lungs for [99mTc]PYP (0.31 rad/mCi) is greater than for [99mTc]DTPA (0.11 rad/mCi), it is at a clinically acceptable and safe level.