2006 · 16 citations · 1 references
EngineeringNuclear EngineeringPhysicsMicroelectronicsPlasma PhysicsRadiation DetectionDetector TechnologyGamma-ray DetectionGamma-ray DetectorsRadiation DetectorsRadiation Imaging DetectorsSemiconductor DetectorsDetector DesignDetector FabricationDirect Conversion DetectorsImaging DetectorsNeutron-gamma DiscriminationPixel DetectorsResponse TimeSemiconductor Radiation Detectors
A new class of radiation detectors has been conceived and demonstrated using plasma panel TV-set technology for direct conversion of ionizing radiation to free-electrons and a gaseous media for electron amplification with a gain of approximately 10 <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">11</sup> . For the basic configuration, a native pixel resolution of 10 mum appears feasible, with a pixel response time of 1 mus or faster, and a manufacturing cost of less than $1 per square inch for detector and electronics. New structures under consideration suggest the possibility that the plasma panel detector could be a transformational technology with low cost, large area, high spatial and temporal resolution, and potentially high efficiency, high energy spectral resolution and high neutron/gamma-ray discrimination
1
Thick silicon strip detector Compton imager
E. Wulf, Bernard F. Phlips, W. N. Johnson et al. · IEEE Transactions on Nuclear Science · 2004 · 17 citations
Engineering, Nuclear Engineering, Nuclear Instrumentation +16