Journal of Clinical Virology · 2015 · 129 citations · 111 references
Veterinary MedicineInfectious DiseasesMicrobiologyDiagnostic MicrobiologyMolecular DiagnosticsVirologyPathogen DetectionRespiratory InfectionsRespiratory Infectious DiseasesRespiratory Pathogen DiagnosticsRespiratory Tract InfectionsViral DiagnosticsNext-generation Sequencing AssaysRespiratory DiagnosticsRespiratory Infection DiagnosisRespiratory Pathogen TestingRespiratory Viral InfectionsRespiratory VirusesViral Respiratory InfectionsVirus Genotypes
BACKGROUND: Molecular assays are the gold standard methods used to diagnose viral respiratory pathogens. Pitfalls associated with this technique include limits to the number of targeted pathogens, the requirement for continuous monitoring to ensure sensitivity/specificity is maintained and the need to evolve to include emerging pathogens. Introducing target independent next generation sequencing (NGS) could resolve these issues and revolutionise respiratory viral diagnostics. OBJECTIVES: To compare the sensitivity and specificity of target independent NGS against the current standard diagnostic test. STUDY DESIGN: Diagnostic RT-PCR of clinical samples was carried out in parallel with target independent NGS. NGS sequences were analyzed to determine the proportion with viral origin and consensus sequences were used to establish viral genotypes and serotypes where applicable. RESULTS: 89 nasopharyngeal swabs were tested. A viral pathogen was detected in 43% of samples by NGS and 54% by RT-PCR. All NGS viral detections were confirmed by RT-PCR. CONCLUSIONS: Target independent NGS can detect viral pathogens in clinical samples. Where viruses were detected by RT-PCR alone the Ct value was higher than those detected by both assays, suggesting an NGS detection cut-off - Ct=32. The sensitivity and specificity of NGS compared with RT-PCR was 78% and 80% respectively. This is lower than current diagnostic assays but NGS provided full genome sequences in some cases, allowing determination of viral subtype and serotype. Sequencing technology is improving rapidly and it is likely that within a short period of time sequencing depth will increase in-turn improving test sensitivity.
111
Fast and accurate short read alignment with Burrows–Wheeler transform
Heng Li, Richard Durbin · Bioinformatics · 2009 · 62.8K citations · Full text
MEGA6: Molecular Evolutionary Genetics Analysis Version 6.0
Koichiro Tamura, Glen Stecher, Daniel S. Peterson et al. · Molecular Biology and Evolution · 2013 · 47.9K citations · Full text
BEDTools: a flexible suite of utilities for comparing genomic features
Aaron R. Quinlan, Ira M. Hall · Bioinformatics · 2010 · 30.4K citations · Full text
Quality control and preprocessing of metagenomic datasets
Robert Schmieder, Robert A. Edwards · Bioinformatics · 2011 · 5.4K citations · Full text