Wound Botulism Complicating Internal Fixation of a Complex Radial Fracture

Steve M. Taylor, Cameron R. Wolfe, Terry C. Dixon, David S. Ruch, Gary M. Cox

Journal of Clinical Microbiology · 2009 · 17 citations · 13 references

DOIFull text

Open access

Concepts

Abstract

Botulism developed in a patient following surgical repair of an open radial fracture. Symptoms resolved after treatment with antitoxin and antibiotics, and hardware excision was deferred. Subsequent osteomyelitis necessitated hardware exchange, and wound cultures grew Clostridium argentinense. This case highlights the management of botulism associated with orthopedic hardware.