Applied Optics · 2015 · 47 citations · 17 references
MedicineOphthalmologyVision ScienceContrast SensitivityOpticsVisual OpticsBiomedical Laser ApplicationsVisual AcuityContrast Threshold TestingEye SafetyIntraocular Light ScatterIrradianceLaser ThresholdLaser-induced EffectsTarget DetectionVisual Optics Modeling
A simple model for laser eye dazzle is presented together with calculations for laser safety applications based on the newly defined Maximum Dazzle Exposure (MDE) and Nominal Ocular Dazzle Distance (NODD). A validated intraocular scatter model has been combined with a contrast threshold target detection model to quantify the impact of laser eye dazzle on human performance. This allows the calculation of the MDE, the threshold laser irradiance below which a target can be detected, and the NODD, the minimum distance for the visual detection of a target in the presence of laser dazzle. The model is suitable for non-expert use to give an estimate of anticipated laser eye dazzle effects in a range of civilian and military scenarios.
17
The Fundamentals of Glare and Visibility
L. L. Holladay · Journal of the Optical Society of America · 1926 · 269 citations
Visibility of targets: Model for calculation
W. Adrian · Lighting Research & Technology · 1989 · 209 citations
Disability Glare A State of The Art Report
J. J. Vos · Medical Entomology and Zoology · 1984 · 208 citations
Education, Ophthalmology, Disability +12
Theoretical Investigations of Laser Thermal Retinal Injury
Reginald Birngruber, Franz Hillenkamp, V.–P. Gabel · Health Physics · 1985 · 201 citations
Medicine, Biophysics, Ophthalmology +14