IEEE Transactions on Industry and General Applications · 1971 · 24 citations · 0 references
EngineeringElectrical EngineeringElectric MachinesElectromagneticsElectromagnetismElectromagnetic InductionHarmonic AnalysisInduction MachinesLosses In Electric MachinesSynchronous MachinesFlux Leakage In Electrical MachinesHarmonic EffectsHarmonicsInduction Motor Equivalent CircuitInduction Motor TheoryInduction MotorsLeakageSingle-phase Induction Motors
An analysis of harmonics of leakage fields which appear in the vicinity of the motor at its symmetric and nonsymmetric supply is presented. The wave at the frequency (2 -s)·f <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">1</sub> , which appears in the second case, may be utilized to protect the motor against single-phase operation.