Current distributions for barbed plate-to-plane coronas

P.J. McKinney, Jane H. Davidson, Douglas M. Leone

IEEE Transactions on Industry Applications · 1992 · 33 citations · 15 references

Concepts

Abstract

Corona current distributions at the ground plane of barbed plane-to-plane negative discharge configurations are measured using an X-Y traversing ground plane containing an electrically isolated probe area. The effects of barb length, barb point radius of curvature, barb pattern, applied voltage, and plane-to-plane spacing on the current distribution are examined. The current distributions are visualized with oxidation patterns on a copper ground plane. Barb tip-to-plane spacing and applied voltage control maximum current density, whereas barb length, barb spacing, and pattern govern current density uniformity. A hexagonal barb pattern is suggested for use in electrostatic precipitators.< <ETX xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">&gt;</ETX>

References

15