European Journal of Cardio-Thoracic Surgery · 2011 · 33 citations · 18 references
MedicineCardiologySurgeryCardiac TransplantationCardiothoracic SurgeryTransplant SurgeryAortic SurgeryGraft SurvivalHeart TransplantationActuarial Survival AnalysisAllograft Survival AssessmentAortic Graft ReplacementAortic Root DiseaseAscending Aorta ReplacementStructural Valve DeteriorationValve Replacement Indications
OBJECTIVE: The study aims to report results of re-operations after aortic allograft root implantation. METHODS: All consecutive patients in our prospective allograft database, who underwent aortic allograft root implantation, were selected for analysis, and additional information for patients who subsequently underwent re-operation was obtained from hospital records. RESULTS: From 1989 to 2009, 262 aortic allograft root implantations were performed. Thirty-day mortality was 5.7%. During follow-up, 69 patients died. The actuarial survival was 77.0% (95% confidence interval (CI) 71-83%) after 10 years, and 65.1% (95% CI 57-74%) after 14 years. A total of 52 patients required re-operation. The actuarial freedom from allograft re-operation was 82.9% (Standard Error (SE) 2.9%) after 10 years and 55.7% (SE 5.7%) after 14 years. The actuarial median time to re-operation was 14.8 years. The indications for re-operation were structural valve dysfunction in 46 patients, endocarditis in two patients and non-structural valve dysfunction in four patients. The re-operations included 23 aortic valve replacements (mechanical prostheses 20 and bioprostheses 3), 27 aortic root replacements (mechanical conduits 21, aortic allografts five, and biological conduit one), one trans-apical valve implantation and one primary closure of a false aneurysm. The additional procedures were mitral valve repair (N = 5), mitral valve replacement (N = 1), ascending aortic replacement (N = 5), and coronary artery bypass grafting (CABG) (N = 4; in two patients unforeseen). Thirty-day mortality after re-operation occurred in two patients (3.9%). Five patients died during follow-up. The survival after re-operation was 87.1% (SE 5.5%) after 1 year and 79.3% (SE 7.4%) after 9 years. CONCLUSIONS: Re-operations after aortic allograft root implantation will be required in a substantial and growing number of patients. These re-operations, although technically demanding, can be performed with satisfying results.
18
HOMOGRAFT REPLACEMENT OF THE AORTIC VALVE
Donald N. Ross · The Lancet · 1962 · 737 citations
Medicine, Cardiology, Surgery +8
Homograft Aortic Valve Replacement in Aortic Incompetence and Stenosis
Brian G. Barratt‐Boyes · Thorax · 1964 · 434 citations · Full text
Medicine, Cardiology, Surgery +11
Ole Lund, Richard Grocott‐Mason, Hassan Elwidaa et al. · Journal of Thoracic and Cardiovascular Surgery · 1999 · 176 citations · Full text
Medicine, Cardiology, Surgery +16