Pulsed thrust measurements using laser interferometry
93
Citations
7
References
1997
Year
EngineeringMeasurementLaser-plasma InteractionInterferometryLaser Plasma PhysicEducationPlasma PhysicsHigh-power LasersThrust StandsCalibrationOptical DiagnosticsLaser InterferometryLaser-based SensorPulse PowerInstrumentationPlasma DiagnosticsPropulsionThrust StandImpulse BitAerospace EngineeringInstrument ScienceElectronic Instrumentation
An optical interferometric proximeter system (IPS) for measuring thrust and impulse bit of pulsed electric thrusters was developed. Unlike existing thrust stands, the IPS-based thrust stand offers the advantage of a single system that can yield electromagnetic interference-free, high accuracy (<2% error) thrust measurements within a very wide range of impulses (100 μN s to above 10 N s) covering the impulse range of all known pulsed plasma thrusters. In addition to pulsed thrusters, the IPS is theoretically shown to be capable of measuring steady-state thrust values as low as 20 μN for microthrusters such as the field emission electric propulsion thruster. The IPS-based thrust stand relies on measuring the dynamic response of a swinging arm using a two-sensor laser interferometer with 10 nm position accuracy. The wide application of the thrust stand is demonstrated with thrust measurements of an ablative pulsed plasma thruster and a quasi-steady magnetoplasmadynamic thruster.