Aerosol Science and Technology · 2014 · 11 citations · 8 references
EngineeringEnvironmental EngineeringAir PollutionAir Quality ManagementAtmospheric ScienceAerosol ScienceAir Pollution MeasurementAir SamplingParticle SizeParticulate MatterWind-tunnel TestingAerosol InstrumentationAerosol Particle Size DistributionAerosol Performance TestingAerosol PropertiesAirborne ParticlesPm10Size-selective SamplingWind Speed Effects
The objective of the present study was to characterize the \nperformance of a federal reference method (FRM) PM \n10 \nsize- \nselective inlet using analysis methods designed to minimize \nuncertainty in measured sampling efficiencies for large particles \nsuch as those most often emitted from agricultural operations. \nThe performance of an FRM PM \n10 \ninlet was characterized in a \nwind tunnel at a wind speed of 8 km/h. Data were also collected \nfor 20 and 25 \nm \nm particles at wind speeds of 2 and 24 km/h. \nResults of the present sampler evaluation compared well with \nthose of previous studies for a similar inlet near the cutpoint, and \nthe sampler passed the criteria required for certification as a \nFRM sampler when tested at 8 km/h. Sampling effectiveness \nvalues for particles with nominal diameters of 20 and 25 \nm \nm \nexceeded 3% for 8 and 24 km/h wind speeds in the present study \nand were statistically higher than both the “ideal” PM \n10 \nsampler \n(as defined in 40 CFR 53) and the ISO (1995) standard definition \nof thoracic particles ( \np \n< \n0.05) for 25 \nm \nm particles leading to the \npotential for significant sampling bias relative to the “ideal” \nPM \n10 \nsampler when measuring large aerosols.
8